home *** CD-ROM | disk | FTP | other *** search
/ PC Electronics Plus 3 / PC Electronics Plus 3.iso / pg143 / pcgen143.eng < prev    next >
Text File  |  1996-10-02  |  10KB  |  218 lines

  1.  
  2.                     PcGenerator 1.43 sept 15 1996  Demo version
  3.  
  4. What it is and what it does
  5. ---------------------------
  6. PcGenerator [PG] uses the Adlib(compatible) synthesizer which is standard
  7. on almost any Soundcard,to turn your PC into a low frequency signal generator.
  8. the Soundblaster (compatible) A/D converter is used to do measurements
  9. in combination with the generator.
  10. PG has all features of a full blown Sine signal generator and more:
  11.  
  12.       *frequency range from 0.5.......25000 Hz
  13.       *precise frequency adjustment in 7 ranges
  14.       *lots of sweep options
  15.       *burst with selectable on/off times
  16.       *output level attenuation in 0.75 dB steps
  17.       *graphical representation of frequency characteristics measurements
  18.       *mouse cursor measurements
  19.       *scope function
  20.       *graphs can be printed
  21.       *user friendly GUI
  22.       *clearly readable 7-segment displays
  23.       *7-segment displays sizeable from small to full screen
  24.       *all functions selectable with mouse and keyboard
  25.       *measurements can be saved and loaded
  26.       *graphs can be exported as PCX's
  27.  
  28. System requirements
  29. -------------------
  30.   + 286+ PC
  31.   + VGA monitor
  32.   + Soundblaster(compatible) soundcard
  33.  
  34. Installation
  35. ------------
  36. in fact there is no installation needed :
  37. PG uses the Adlibsynthesizer address 388h,which is standard on almost
  38. all soundcards.the DSP(A/D convertor) address is 220h which is also
  39. standard.no interrupt is used.
  40. the printer should be Epson compatible.
  41.  
  42. Soundcard setup and connection
  43. ------------------------------
  44. in principle all SB compatible cards can be used,but some are more
  45. suitable than others.
  46. PG works ok with the SB 2.0 and 100% clones,the SB Pro and clones,the
  47. SB 16 and many others.
  48.  
  49. some cards have a loudness option,this should be switched off.
  50.  
  51. as generator output both the line-out(when available) and speaker-out
  52. can be used.when the speakerout is used,no monitor speakers should be
  53. connected:this can weaken and distort the output,especially with low
  54. frequencies.
  55.  
  56. as measurement input only the line-in should be used:most mike inputs
  57. have a bad frequency responce and some have a buildin compressor.
  58.  
  59. with stereo card one channel must be used as generator,the other as
  60. measurement input.on most cards this must be set up with a utility
  61. program.setup example:
  62. Left  synthesizer 100% line-in 0%.
  63. Right synthesizer 0%  line-in 100%.
  64. as input line-in should be selected of course.
  65.  
  66. functions and keys
  67. ------------------
  68.  
  69. function         key               displaycolor         discription
  70. --------------------------------------------------------------------
  71. ON               ENTER                RED               Generator on.
  72. OFF              ENTER                GREEN             Generator off.
  73. FreqUp           Uparrow                                freq. one step up
  74. Freqdown         Downarrow                              freq. one step down
  75. FS 1..100        Left/Rightarrow                        Freq. step size
  76. Help             F1                                     Help
  77. SweepStart       F2                   LIGHTBLUE         Sweep start freq.
  78. SweepStop        F3                   DARKBLUE          Sweep stop freq
  79. SweepGo          F4                                     begin Sweep
  80. SweepGoShFr      F5                   LIGHTBLUE         begin Sweep with display
  81. P                F6                                     print Grafiek
  82.                  F7                                     REFsweep
  83.                  AltF                 WHITE             REFfrequentie
  84. Cor On/Off       F8                                     correction on/off
  85. Z                F9                                     Open Grafiek window
  86. SweepGraf        F10                                    Measurement Sweep
  87. SweepMul         ALTM                                   Multi Meas. Sweep
  88.                  ALTS                                   Reset Multi Sweep
  89. Scope            ALTO                                   Scope
  90. Burst                                 YELLOW            begin Burst
  91. Multipl. 0.5..6  ~..6                                   freq. multiplier
  92. BurstOn  5ms..5s                                        Burst On time
  93. BurstOff 5ms..5s                                        Burst Off time
  94. Sweeptime                                               Sweep time
  95. Sweeptimex                                              Sweeptime multiplier
  96. log/lin                                                 liniair/log Sweep
  97. level -          -                    GREY              level down
  98. level +          +                    GREY              level up
  99. -                esc                                    close window
  100. stop             AltX                                   stop PG
  101. -----------------------graph window buttons---------------------------------
  102. G                                                       Grid on/off
  103. T                                                       Graph title text
  104. C                                                       Cursor measurement on/off
  105. R                                                       Redraw graph
  106. S                                                       Save graph
  107. L                                                       Load graph
  108. X                                                       Save graph as PCX
  109. O                                                       Scope
  110.  
  111. short explanation
  112. -----------------
  113. PG uses a GUI with windows (NOT MS-Windows) and the mouse.
  114. every computer user should be familiar with this kind of user interface
  115. now a day.some remarks on this subject:
  116. windows can be moved and sized.don't make windows larger then necessary,
  117. close windows you don't need.don't put large windows over smaller one's.
  118. all this will slow down PG.
  119.  
  120. most functions will be clear or become clear soon for the intended user
  121. (sound techician,electronic technician,etc).below a short explanation.
  122.  
  123. the most important function of PG -apart from it's use as a normal
  124. signal generator-is SweepGraph.this function sweeps through a certain
  125. frequency range and the frequency response is being measured at the
  126. same time.
  127. after the Start and Stop frequencies have been set and the system to be
  128. measured has been connected,the measurement starts with SweepGraph or
  129. F10.Sweeping goes on continuously and the input becomes visible in the
  130. SweepGraph window.the proces can be stopped at any point after which
  131. the Graph can be made visible with Z or F9.the frequency scale is
  132. adjusted automatically.a Graph title can be chosen and the Graph can be
  133. printed or exported as PCX.
  134.  
  135. with the mousecursor cursor measurement can be done in the Graph window:
  136. the cursor is to be moved over the Graph and a small magenta line becomes
  137. visible,the exact frequency at that point can be read from the Frequency
  138. window.the left mouse button can be used to put frequency readings in the
  139. Graph.
  140.  
  141. Multisweep works almost the same way as Sweepgraph,but now a total of 7
  142. measurements can be done in one Graph.the proces cannot be stopped in
  143. between: sweeping stops at the end of the selected frequency range,after
  144. which a new measurement can be started.
  145. ALT-S can be used to reset Multisweep,to start a new serie.
  146.  
  147. the 'X' button exports a Graph as PCX,the generation of the PCX file may
  148. take one or two seconds,the mousecursor returns after completion.
  149. not all Viewers can read this PCX's correctly,the reason for this is not
  150. clear to me.Neopaint (3.0) reads them ok,so you can use this program
  151. to convert if necessary.
  152. the ".pcx" extension is added automatically.
  153.  
  154. the Scope function is not a full blown oscilloscope for serious
  155. measuring purposes.Low frequency program material such as speech
  156. and music can be made visible fairly good though.
  157. experiment with the delay and display rate setings these are
  158. hardware dependent
  159.  
  160. measurements can be saved with 'S' and loaded with 'L'.
  161. a saved MultiSweep can be compared with a new measurement: the new
  162. measurement is simple done as the next Sweep.
  163. the ".gen" extension is added automatically.
  164.  
  165. printing only works with Graph window opened:printing is done with a
  166. screendump.printing can be interrupted with ESC.
  167.  
  168. Demo Version
  169. ------------
  170. the Demo version has some limitations and a Demo message is shown
  171. at the start and end of the program.
  172. the complete version is fl. 35.- ( US $ 20.-) per user licence.
  173. to order the order form must be send by E-mail or mail.
  174. after payment has been received,the complete version will be send
  175. to you by E-mail or mail(3.5 disk add US $ 5.- for P&P).
  176. the complete version will be personalised:your name will be shown at the
  177. start of the program.
  178. registered users can call me for telefonic support.update releases
  179. will be send to you free (E-mail only).
  180.  
  181.   The Registered Version of this program can also be purchased and received
  182.   immediately on the Internet at Albert's Ambry.  Registration at Albert's
  183.   also eliminates shipping and handling costs.  Please go to:
  184.  
  185.       http://www.alberts.com
  186.  
  187.   Search on: >>PG143.zip<<
  188.  
  189.   Click on the "Buy It" Hotlink to register this software.
  190.  
  191.   Thank you for registering this program.
  192.  
  193. this program can be freely distributed.
  194.  
  195.  Willem Kloosterhuis
  196.  
  197.  E-mail waklos@bos.nl
  198.  website:www.bos.nl/homes/waklos/
  199.  tel:31(0)318-653068
  200.  
  201. rev. history
  202. 1.00     20-3-95    first release
  203. 1.01     14-4-95    some minor bugs,diverse docs added.
  204. 1.2      12-1-96    some bugs.7-segments display improved
  205. 1.3      15-4-96    MultiSweep en Cursor measurement added.
  206. 1.31     16-4-96    bugfix update.multisweep corrected
  207. 1.40     15-5-96    Save,Load en PCX Save added.
  208. 1.41     25-5-96    some improvements of Save,Load en PCX Save added.
  209. 1.41c    15-7-96    PCX save improved (most viewers read correct now)
  210. 1.42     15-8-96    Screensaver added
  211. 1.43     15-9-96    Scope function added
  212.  
  213.  
  214.  
  215.  